| Go
Back |
 |
Enterprise
CS Specifications |
|
System
Resources |
|
TYPE |
MAXIMUM
CAPACITY |
| Universal Card Slots |
35 |
| Gateway Controllers (IX-CME) |
1 |
| Expansion Modules (Phase 1) |
5 APS cabinets
(fully expanded ADIX 450 or ADIX-M may also be
used) |
| Expansion Modules (Phase 1.5) |
5 Enterprise-CS
Expansion Modules |
| Expansion Modules (Future) |
10 Enterprise-CS
Expansion Modules |
| MBU Channels for IP Devices |
IMBU/96 channels |
| IP Addresses (DHCP) |
1024 |
|
|
Trunks
|
|
TYPE |
MAXIMUM
CAPACITY |
| Total
TDM Hardware Trunk Ports |
616* |
|
|
Stations
|
|
TYPE |
MAXIMUM
CAPACITY |
| Total
Station Ports |
1024 |
| TDM
Hardware Station Ports |
520* |
| Total
IP Terminals |
1024 |
| Omegatrek
PS6 Portable Stations |
992 |
| IX-BS5
Base Stations (TDM and IP) |
140 |
| Total
Attendant Positions |
32 |
| DSS
Units |
128 |
| Analog
Stations |
396* |
| Door
Phones |
455* |
| Busy
Bypass Units |
228 |
| Programmable
Key Patterns |
1024 |
|
|
Networking
|
|
TYPE |
MAXIMUM
CAPACITY |
| Campus
Over IP |
|
| Total
Campus Resources |
1024 |
| Total
Resources per Node |
512 |
| Total
Campus Nodes |
16 |
| Campus
Over T1 |
|
| Total
Campus Nodes |
15 |
| PBX
to PBX (Conventional Networking) |
IMBU/96 channels |
| E&M
Tie Trunks |
140* |
| T1
Cards (IX-DTI-T) PBX to PBX Networking |
10 |
| IP-NET
Cards |
62 |
| IP-NET
Maximum Remote Systems |
128 |
|
|
*
Assumes IX-CML expanded to a full size ADIX APS with IX-PWSL
on each shelf.
|
|
Miscellaneous
Function
|
|
TYPE |
MAXIMUM
CAPACITY |
| Miscellaneous
Functions Ports |
512 |
| Music-on-Hold
Sources |
1 |
| Serial
Ports for SMDR, ACD Reporting |
1 |
| Serial
Ports for Maintenance |
1 |
| Ethernet
Ports for SMDR and ACD Reporting |
1 |
| Ethernet
Ports for Maintenance |
1 |
| Conference
Circuits |
4
party conference, 32 rooms |
|
|
Software
Specifications
|
|
TYPE |
MAXIMUM
CAPACITY |
| Station
Ring Groups |
255 |
| Outgoing
Trunk Groups |
255 |
| Incoming
Trunk Groups |
255 |
| Hunting
Groups |
255 |
| Maximum
Stations per Hunting Group |
32 |
| Paging
Groups |
255 |
| Maximum
Station per Paging Group |
32 |
| External
Paging Zones |
128 |
| ACD
Groups |
255 |
| Maximum
Agents per ACD Group |
512 |
| Maximum
Number of ACD Agents |
1024 |
| Maximum
Number of Active ACD Agents |
512 |
| UCD
Group |
255 |
| Meet-Me-Group |
255 |
| Call
Pickup Group |
255 |
| Toll
Restriction Group |
32 |
| Text
Message Group |
250 |
| Stations
per Text Message Group |
64 |
| Station
Numbering Plan |
Flexible
up to 4 digits |
|
|
|
| Go
Back |
|